Step 1: Review Items Included In This Set:
Enlarge Image
80 kW Generac Liquid-Cooled Generator, CSA, EPA Compliant in Steel Included In Set
Qty: 1 included
Usually ships in 4 to 6 weeks
Voltage: Select Voltage 120/208, 3 Phase
120/240, 1 Phase
277/480, 3 Phase
Fuel: Select Fuel Natural Gas
Propane Vapor
Step 2: Save On Additional Pieces:
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/240, 1 Phase, Nema 1
120/208, 3 Phase, Nema 1- add $98.00
277/480, 3 Phase, Nema 1- add $269.00
120/240, 1 Phase, Nema 3R- add $310.00
120/208, 3 Phase, Nema 3R- add $405.00
277/480, 3 Phase, Nema 3R- add $578.00
Usually ships in 3 to 5 days
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/240, 1 Phase, Nema 1
120/208, 3 Phase, Nema 1- add $94.00
277/480, 3 Phase, Nema 1- add $289.00
120/240, 1 Phase, Nema 3R- add $309.00
120/208, 3 Phase, Nema 3R- add $403.00
277/480, 3 Phase, Nema 3R- add $562.00
Usually ships in 3 to 5 days
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/240, 1 Phase, Nema 1
120/208, 3 Phase, Nema 1- add $328.00
120/240, 1 Phase, Nema 3R- add $369.00
277/480, 3 Phase, Nema 1- add $417.00
120/208, 3 Phase, Nema 3R- add $636.00
277/480, 3 Phase, Nema 3R- add $823.00
Usually ships in 3 to 5 days
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/240, 1 Phase, Nema 1
120/208, 3 Phase, Nema 1- add $265.00
120/240, 3 Phase, Nema 1- add $265.00
120/240, 1 Phase, Nema 3R- add $309.00
277/480, 3 Phase, Nema 1- add $422.00
120/208, 3 Phase, Nema 3R- add $575.00
120/240, 3 Phase, Nema 3R- add $575.00
277/480, 3 Phase, Nema 3R- add $730.00
Usually ships in 3 to 5 days
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/240, 1 Phase, Nema 1
120/208, 3 Phase, Nema 1- add $140.00
120/240, 1 Phase, Nema 3R- add $309.00
120/240, 3 Phase, Nema 1- add $321.00
277/480, 3 Phase, Nema 1- add $324.00
120/208, 3 Phase, Nema 3R- add $630.00
120/240, 3 Phase, Nema 3R- add $630.00
277/480, 3 Phase, Nema 3R- add $772.00
Usually ships in 3 to 5 days
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/208, 3 Phase, Nema 12
120/240, 1 Phase, Nema 12
120/208, 3 Phase, Nema 3R- add $47.00
277/480, 3 Phase, Nema 12- add $76.00
120/240, 1 Phase, Nema 3R- add $135.00
277/480, 3 Phase, Nema 3R- add $188.00
Usually ships in 3 to 5 days
Enlarge Image
Voltage/Enclosure: Select Voltage/Enclosure 120/208, 3 Phase, Nema 12
120/240, 1 Phase, Nema 12
277/480, 3 Phase, Nema 12- add $90.00
120/240, 1 Phase, Nema 3R- add $281.00
120/208, 3 Phase, Nema 3R- add $359.00
277/480, 3 Phase, Nema 3R- add $449.00
Usually ships in 3 to 5 days
Since 1959, Generac Power Systems, Inc. has been a leading, innovative manufacturer and marketer of portable and standby generators, automatic transfer switches, modular paralleling systems, and small engines for recreational vehicle, residential, and...
More on Generac...
Generac QT08046 -Steel - 80 kW Liquid-Cooled Generator, CSA, EPA Compliant
This steel generator is ideal for a broad range of enterprises, including restaurants, convenience stores, supermarkets, banks, fitness centers, hotels, and retail outlets. Keep your business "in business" and protect your revenue stream by investing in a reliable yet affordable back-up power source. One of the quietest liquid cooled generators on the market this model features the exclusive patent-pending Whisper-Test low speed generator test cycle which reduces noise by 50%. Achieves near silent operation that satisfies all known sound ordinances.
Features:
Steel enclosure
Liquid cooled engine produces more electricity for longer outages
Whisper-Test™: Patent-pending, self-test feature makes the GUARDIAN Elite 50% quieter during the generator’s weekly self-test cycle
Longest life expectancy in the industry: Over 3,000 hours of run time
Superior Paint: Tough, textured powder coat finish for unmatched durability and all weather protection
UL listed
Clean burning fuel: Natural gas or liquid propane vapor
Generator Specifications:
Rated Power LPG (kW): 80
Rated Power NG (kW): 80
Amps @ 240V, 1 Phase: 333
Amps @ 208V, 3 Phase: 278
Amps @ 480V, 3 Phase: 120
Voltage @ 60 Hz: (120/240, 1 Phase), (120/208, 3 Phase), (277/480, 3 Phase)
Phase: Single and Three Phase
Frequency: 60 Hz
Engine/Alternator RPM: 3600/3600
Engine: 4.6L V-8
Fuel: Natural Gas or Liquid Propane Vapor
Fuel Consumption LP (cu.ft/hr)/(gal/hr): 465/12.78
Fuel Consumption NG (cu.ft/hr): 1154
EPA CARB Certified: NO
Engine Cooling: Liquid
Controls: H-100
UL 2200 (US and Canada): YES
Main Line Circuit Breaker: 350,300,150 Amp
An Automatic Transfer Switch makes the difference between a truly automatic generator set and just another generator. When the power goes out, this switch automatically senses the failure, turns on your generator, and routes electricity to the circuits of your home. No toggles to flip, no knobs to turn, no extension cords to run during a blackout. You will have the comfort and peace-of-mind knowing that your Guardian stand-by generator does everything for you...automatically!
Automatic Transfer Switch (HTS-N) Features:
Single coil design, electrically operated and mechanically held
Programmable exercise time
SPDT aux contacts
Main contacts are silver alloy
Conformal coating protects the printed circuit board
UL 1008 listed
Indicating LED's for switch position, standby operating, and utility available
3 positions test switch: Fast test, auto, normal test
Arc chutes on main contacts
Signal before transfer contacts
Rated to all classes of loads
Remote start, stop and transfer through GenLink Communications Software
100 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neutral
Terminal Lug Wire Contact Terminals: 2/0 - 14 AWG
Number of Lugs: 4
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 14,000
Maximum Fuse Size: 200 Amps
Fuse Class: J, T
150 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neutral
Terminal Lug Wire Contact Terminals: 400MCM - 4 AWG
Number of Lugs: 4
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 25,000
Maximum Fuse Size: 400 Amps
Fuse Class: J, T
200 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neutral
Terminal Lug Wire Contact Terminals: 400MCM - 4 AWG
Number of Lugs: 4
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 25,000
Maximum Fuse Size: 400 Amps
Fuse Class: J, T
300 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neurtal
Terminal Lug Wire Contact Terminals: 600MCM - 4 AWG or (2)250MCM-1/0 AWG
Number of Lugs: 4
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 35,000
Maximum Fuse Size: 600 Amps
Fuse Class: J, T
400 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neurtal
Terminal Lug Wire Contact Terminals: 600MCM - 4 AWG or (2)250MCM-1/0 AWG
Number of Lugs: 4
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 35,000
Maximum Fuse Size: 600 Amps
Fuse Class: J, T
600 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neurtal
Terminal Lug Wire Contact Terminals: Two Lugs per pole - 500MCM - 1 AWG
Number of Lugs: 8
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 42,000
Maximum Fuse Size: 800 Amps
Fuse Class: L, T
800 Amp Automatic Transfer Switch (HTS-N) Specifications:
Designed to operate in conjunction with the Generac H100 Series generator controller
2-wire RS485 communication link to the generator controller
Switch operation is instigated by the generator controller
All timers and voltage set points are programmable through GenLink Communications Software
Standby Accept Voltage: 85-95%
Standby Accept Frequency: 85-95%
Nominal Voltage: 1 Volt Increments
Allowable Deviation of Utility: 1 - 100%
Line Interruption Delay: 1 - 10 seconds
Engine Warmup Time: 1 - 300 seconds
Minimum Run Time: 5 - 60 min.
Return to Utility Timer: 1 - 30 min.
Engine Cooldown Timer: 1 - 30 min.
Signal Before Transfer Timer: 1 - 30 sec.
Transfer Type: Inphase Time Delay Neurtal
Terminal Lug Wire Contact Terminals: 4 Lugs per pole - 500MCM - 4/0 AWG
Number of Lugs: 12
Maximum RMS Symmetrical Faul Current: Fuse - 200,000 Amps, Circuit Breaker - 65,000
Maximum Fuse Size: 1200 Amps
Fuse Class: L
Item:
Weight:
Dimensions:
80 kW Generac Liquid-Cooled Generator, CSA, EPA Compliant in Steel
2010 lbs
54.8" H x 36.8" W x 115.2" D
100 Amp Automatic Transfer Switch (HTS-N)
180 lbs
36" H x 24" W x 10" D
150 Amp Automatic Transfer Switch (HTS-N)
185 lbs
36" H x 24" W x 10" D
200 Amp Automatic Transfer Switch (HTS-N)
185-265 lbs
36-48" H x 24-30" W x 10-12" D
300 Amp Automatic Transfer Switch (HTS-N)
245-325 lbs
Unavailable
400 Amp Automatic Transfer Switch (HTS-N)
245-325 lbs
Unavailable
600 Amp Automatic Transfer Switch (HTS-N)
650 lbs
Unavailable
800 Amp Automatic Transfer Switch (HTS-N)
650 lbs
Unavailable